Voltage Multiplier
Simulation File
V5-V7
are DC voltage nodes, like a DC voltage 'Lock'. The peak voltage of the
sine wave will be stored as a DC voltage in the 'dead zone'. V2, V3,
and V4 will oscillate based on that DC offset voltage (V5 and V2 has a
diode to conduct the DC but block AC). Every stage has a higher DC
offset, and the AC will sit on a higher DC offset. Every stage will
increase the volgtage by the the value of the original amplitude.